FDK-2022-8066
Auxetic structures are special structures with negative Poisson's ratio due to their geometric shapes in their internal structure. When tensile force is applied to these structures, transverse and longitudinal expansions are observed, while transverse and longitudinal contractions are observed when compressive force is applied. There are many different unit cell designs such as chiral, arrowhead, re-entrant in auxetic structures. In this study, a unique cell design was studied and the behavior of an auxetic lattice structure was investigated. The lattice structure designed with different geometric thicknesses and different matrices was analyzed with the finite element analysis program and found to have a negative Poisson's ratio. In the designed lattice structure, the structure with 4×4 matrix and 3 mm geometric thickness was found to have the best negative Poisson's ratio.
Gazi Üniversitesi BAP
FDK-2022-8066
Finansal destek için Gazi Üniversitesi BAP birimine (Proje no: FDK-2022-8066) teşekkür ederiz.
Primary Language | English |
---|---|
Subjects | Material Design and Behaviors, Mechanical Engineering (Other) |
Journal Section | Tasarım ve Teknoloji |
Authors | |
Project Number | FDK-2022-8066 |
Early Pub Date | November 25, 2023 |
Publication Date | December 28, 2023 |
Submission Date | September 27, 2023 |
Published in Issue | Year 2023 Volume: 11 Issue: 4 |